Tips and Tricks to Crack ASE 2000 v1.56 26 and Diagnose SCADA Issues



Download the latest release of the Standard Version of the ASE2000 Communication Test Set. This service is available currently licensed users of the ASE2000, or to those who need to view a capture file. The software requires the ASE2000 hardware and licence key to operate.


This documentation is used with both the Standard Version and the Trial Version of the ASE2000 software. Trial Version users should be sure to read the Trial Version Introduction before attempting to load and use the Trail Version software. File size approximately 7.5 MB.




crack ase 2000 v1.56 26




ASE provides a comprehensive product for utility protocol testing with its PC-based protocol test solution. The ASE2000 RTU Testset is a full-featured protocol test system that provides the user with a powerful and flexible tool for testing and maintaining SCADA RTU and SCADA IED equipment and diagnosing communication problems. With support for DNP3, IEC60870-5-101, IEC 60870-5-104, and 80+ protocols, it is by far the most comprehensive Testset available. It supports Windows 10, 11 and legacy Windows (Windows 7, 8, XP (SP2, SP3), Vista).


All protocols are supported in a single program with a single user interface, so that you can test DNP3, IEC 60870-5-101, IEC 60870-5-104, CONITEL, CDC, and more with the same software. The ASE2000 provides a total solution approach to the area of protocol test equipment software and its family of PC-based protocol test equipment that includes USB serial communication hardware and Bell-202 modems.


ASE2000 Version 1 was first introduced in 1999 (replacing older Comm/32 and Comm/64 models) and has a current installed base of several thousand units in numerous utilities and SCADA industry companies worldwide. Version 1 testset supported DNP3, IEC 60870-5-101, IEC 60870-5-104, and 80+ protocols. It continues to be used as the preferred DNP3 Protocol Testset or DNP3 Protocol Simulator.


ASE2000 Version 2 Testset, introduced in September 2011, expands on Version 1 features by supporting operation in Exchange and Task modes. Exchange mode implements Version 1 features and operation. Task mode, new in Version 2, adds a simplified means to perform a set of common tasks such as device initialization, data acquisition, controls, and file transfers. Task Mode operation requires only that the user select an RTU/IED device and a task to be performed. Communication message editing, frequently required in Version 1, is automated in Version 2. Version 2 supports DNP3, IEC 60870-5-101, IEC 60870-5-104, and 80+ protocols. Today, Version 2 is the most preferred DNP3 Protocol Testset, DNP3 Protocol Simulator, IEC 104 Protocol Testset, and IEC 60870-5-104 Protocol Simulator.


The ASE2000 RTU Testset is a full-featured DNP3 protocol simulator, IEC 60870-5-104 protocol simulator, IEC 60870-5-101 protocol simulator, 80+ Legacy protocol simulators, and test set, which provides the user with a powerful and flexible tool for testing and maintaining SCADA RTU and SCADA IED equipment and diagnosing communication problems.


ASE2000 operation is a menu-driven, window-oriented interface, developed in line with standard Windows interface presentation guidelines. Set-up screens allow the user to define test session-specific information and user preference information. For quick-start operation, the supplied default values for most test operations are sufficient and preclude the need for lengthy and complicated pre-test set-up. For tests that do require special conditions, a set of intuitive and easy-to-use set-up screens is provided. Special set-up conditions can be saved to uniquely named files and easily retrieved for use in future sessions. Many users develop a library of frequently used test scenarios with this feature, thereby eliminating repetitive set-up for future test sessions.


Modes of Operation (Version 1 and Version 2/Exchange Mode)The ASE2000 test set has three modes of operation: Master Simulation (communicating to a downstream device or RTU), RTU Simulation (communicating to a master station), and Line Monitor (listening to communications between Master and RTU/IED devices).


RTU Simulation Mode allows the user to configure the ASE2000 RTU test set as one or more RTUs to respond to data scan requests and supervisory control commands. Convenient set-up menus allow the user to specify point types, number of points, and point order that will result in the proper data message structure. Point modeling can also be enabled to provide data value changes on successive data scans.


Line Monitoring Mode is used to monitor communication between a master station and all RTU/IED devices on a communication line. Message data for both directions is shown. Line monitoring is available for Serial Bit / Byte and Network protocols. If you are running ASE2000 as a DNP3 Protocol Testset or IEC 60870-5-104 Protocol Test Set in monitor mode, you can listen on the network and see the DNP3 or IEC 104 protocol traffic in the network and see the traffic and exchanges between SCADA and RTU.


ASE2000 Version 2 adds Task Mode. In this mode, the ASE2000 operates from a user-defined RTU/IED device database. Each definition includes counts and addresses of all input points at that device.


Task Mode/RTU Simulation allows individual points states/values to be entered from the Point Values view. New values are transmitted in the next applicable scan response, with timestamps if appropriate to the protocol. In addition, the user can define point modeling parameters to automatically generate point changes. Task mode RTU simulation supports DNP3, IEC 60870-5-104, IEC 60870-5-101, and most other protocols supported by ASE2000 Test Sets.


DNP3 Certification testing support files are included with the ASE2000 Version 2 software at no additional charge. An automated test results report can be generated through a standard browser.


The ASE2000 RTU Testset is available in various models that differ only by communication hardware; the software is identical. The ASE2000-COM supports Asynchronous Byte and Network protocols only. Standard PC COM ports cannot support bit-oriented communication used by many of the older legacy protocols.


Model ASE2000-USB-M includes all the hardware provided in the ASE2000-USB-RS, plus a dual-channel Bell-202 modem. The modem is powered by the BCOM-USB device. The same software is provided for the model ASE2000-USB-M as for the model ASE2000-USB-RS. So all your popular protocols, like DNP3, IEC 60870-5-104, and IEC 60870-5-101, will continue to work with ASE2000-USB-M.


The ASE2000-COM utilizes standard PC COM ports and is suitable for users that require support for asynchronous byte-oriented and network protocols only, all using standard PC hardware or USB to serial devices manufactured by others. The ASE2000-COM model: 2ff7e9595c